Leader in providing sales and service in the ophthalmic community. More →

Leader in providing sales and service in the ophthalmic community. More →

Haag-Streit Octopus 900

The Octopus 900 offers all commonly used standard static tests. For central field testing there are the physiology-based G-patterns following the retinal nerve fibers and the 32, 30-2 and 24-2 patterns. For the macula, there are the physiology-based M pattern and the 10-2pattern. With the fast TOP strategy, full threshold testing can be completed in just 2-4 minutes. The commonly used binocular Estermann test, as well as a neurological and a peripheral glaucoma pattern are also included.

View Your Quote Cart
Categories: , Tag:

Description

The Octopus 900–the only modern-day successor to the Goldmann kinetic perimeter

Octopus 900 Basic System

Features include:

  • Disease based programs with Octopus Glaucoma(G) & Macula(M) programs. Capable of doing 24-2, 30-2 & 10-2 programs
  • TOP Strategy for results in less than 3 minutes per eye. Also includes Dynamic & Normal Strategies
  • 100% reliability regarding fixation with Octopus Fixation Control
  • Full 90-degree static tests, including: Estermann & Blepharoptosis
  • 1 isopter III4e Goldmann kinetic test
  • EyeSuite Global Trend Progression Analysis, as well as, Cluster & Polar Trend Analysis
  • Remote database capabilities for shared software and viewing stations
  • Separate computer, monitor, printer & wheelchair accessible table

Octopus 900 Pro System

Includes all Octopus 900 Basic features plus:

  • Manual & semi-automated Goldmann kinetic testing
  • Custom Static testing
  • Blue/Yellow (SWAP), Flicker & Red/White methods
  • Cluster and Polar Trend in EyeSuite Progression Analysis Software
  • Remote database capabilities for shared software and viewing stations
FULL FIELD STATIC PERIMETRY

Everything you need

The Octopus 900 performs standard white-on-white threshold testing in just 2–4 minutes in the central visual field. With its comprehensive test library for central and peripheral tests and its flexible printouts both in Octopus and HFA-format it covers all your clinical needs.

COMPREHENSIVE TEST LIBRARY

A test for any situation

The Octopus 900 offers all commonly used standard static tests. For central field testing there are the physiology-based G-patterns following the retinal nerve fibers and the 32, 30-2 and 24-2 patterns. For the macula, there are the physiology-based M pattern and the 10-2pattern. With the fast TOP strategy, full threshold testing can be completed in just 2-4 minutes. The commonly used binocular Estermann test, as well as a neurological and a peripheral glaucoma pattern are also included. And if you’re still missing a test, why not create it yourself with the Custom Test option?

OCTOPUS PRINTOUT

Standard Octopus representations

Look at visual field results the way you are used to from your Octopus perimeter. All Octopus perimeters offer the standard 7-in-1 printout with its well-known representations, a customizable 4-in-1 printout, a serial printout and much more. And why not conveniently view results in your office by networking your Octopus to the EyeSuite software on your computer?

HFA-STYLE PRINTOUT

Smooth transition from HFA

Enjoy a smooth transition from a HFA to an Octopus perimeter. All Octopus perimeters allow you to import your historic HFA data. Because raw data is imported, you can display your historic and new data in the same format of your choice, either as an HFA-style printout or in the Octopus format.

EYESUITE GLAUCOMA ANALYSIS

A clear view on glaucoma

Get the most out of your glaucoma visual field with the highly sensitive Cluster Analysis, the intuitive Polar Analysis for structural comparisons and the easy-to-interpret EyeSuite Progression Analysis.

EYESUITE PROGRESSION ANALYSIS

Immediate identification of true change

Immediately identify levels of change with the EyeSuite Progression Analysis. It not only reveals whether change is significant, but also whether it is local or diffuse and how fast the change happening. For an effective clinical workflow, all results are displayed using intuitive graphical symbols and can be viewed directly in your office if the Octopus is networked.

CLUSTER ANALYSIS/TREND

Sensitive glaucoma analysis

The sensitive Cluster Analysis groups visual field defects along nerve fibre bundles and combines high sensitivity with good specificity to detect early glaucomatous changes. Significant defects are highlighted and the cluster defects can be used for structural comparison. Cluster Analysis is available in both single field and trend view.

POLAR ANALYSIS/TREND

For intuitive structural comparison

Combining the results of both structure and function is key to obtaining a comprehensive assessment of the onset and progression of glaucoma. The Octopus Polar Analysis projects local visual field defects along the nerve fibers to the optic disk and displays them oriented as structural results. This makes structure-function correlation almost intuitive. Polar Analysis is available in both single field and trend view.

SEMI-AUTOMATED KINETIC PERIMETRY

The modern Goldmann perimeter

Appreciate the same characteristics and kinetic flexibility as offered by the original Goldmann perimeter and further benefit from simplified and more consistent operation.

Comparable to the manual Goldmann perimeter

Enjoy the characteristics of the manual Goldmann perimeter in a modern device with automatic electronic data filing. As with the manual Goldmann perimeter, you can place vectors anywhere you want and even draw them manually in the standard Goldmann sizes, I to V, and intensities, 1a to 4e. In this way, you can achieve diagnostic results comparable to those from a manual Goldmann perimeter.

Simplified and more consistent operation

Benefit from the flexibility of a manual Goldmann but enjoy simplified and more consistent operation. Vector speed is now controlled and thus repeatable; the influence of both operator and patient reaction time is mostly eliminated and normal isopters provide guidance. And why not translate your standard clinical testing protocol into a template for all your patients that you can still adapt depending on the pathology?

FIXATION CONTROL

Perimetry you can trust

Enjoy the reliability of Octopus perimeters, for example with Octopus Fixation Control which automatically eliminates fixation losses from your visual field testing.

Automatically eliminate fixation losses

Fixation losses due to low patient compliance are a major cause of unreliable visual fields. But you needn’t worry any more. Fixation Control interrupts testing, when there is fixation loss, and automatically restarts, when the patient is properly fixating again. This ensures that each visual field point is reliably tested.

EYESUITE

Easy integration in your practice workflow

The EyeSuite software has been designed for optimum patient flow in busy practices. It controls all Haag-Streit devices and allows for them to be networked with other Haag-Streit devices, your office computer and your EMR system without the need for any expensive third-party software.

Octopus900 EyeDistance ApplicatioNote

EyeSuyite i9 Perimetry – performing a kinetic exam

EyeSuyite i9 Perimetry – performing a static exam Octopus 900

EyeSuyite i9 Perimetry – reviewing test results

Title

Go to Top